Each neoBLUE radiometer is individually calibrated to a standard that is traceable to the National Institute of Standards & Technology (NIST) and a calibration certificate is provided for hospital reference. The advanced microprocessor electronics improve linearity and reliability. Its auto-ranging facility automatically measures irradiance from 0.1 to 150.0 ?W/cm2/nm and the dome diffuser on its sensor minimizes angular sensitivity. The neoBLUE radiometer measures spectral irradiance of LED light sources in the blue spectrum and is intended for use with the neoBLUE LED Phototherapy product. Natus Medical Incorporated DBA Excel-Tech Ltd.

distributed by Natus Medical Incorporated, its subsidiaries or affiliates. This versatile system uses the same proven and trusted algorithms with automated, pre-set screening parameters that have been used in millions of screenings1, so you can feel confident in the quality of your results. The large, clear display makes it easy to use & read under all lighting conditions. The light output was factory calibrated with the neoBLUE Radiometer to provide an initial intensity of 35 ☓.5 W/ cm²/nm at the high setting and 15 ☒ W/cm²/nm at the low setting at a distance. The all new Echo-Screen III hearing screener combines advanced capabilities never before available in a single device. The arrangement of LEDs in diffuser panel allows light to cover maximum surface area of the baby. LEDs have minimal light output degradation over their lifetime with proper use. Para garantizar la seguridad del operador, del técnico y del paciente, utilícelo sólo como se especifica en este manual.
Natus neoblue radiometer manual#
It does not accurately measure broadband sources such as halogen or fluorescent. The neoBLUE compact light is also equipped with a white exam light feature that provides approximately 10,000 lux of neutral white light for general examinations. 002717RevDneoBLUE RADIOMETER MANUAL- SPANISH.pdfRadiometer PRECAUCIÓN Lea este manual y familiarícese con él antes de poner a funcionar o reparar este dispositivo. This product is suitable only for measuring with neoBLUE products.

The neoblue radiometer instead was designed specifically for measurement of the led. Intended Use The neoBLUE LED Phototherapy Radiometer is a spectroradiometer for measuring the irradiance (radiant power) of neoBLUE light-emitting diode (LED) phototherapy devices. It helps you comply with AAP guidelines by providing accurate readings in blue spectrum as it measures action spectrum of bilirubin 420 to 500 nm. Per the natus calibration report, the unit was found to be with in. The neoBLUE radiometer measures spectral irradiance of LED light sources in the blue spectrum and is intended for use with the neoBLUE LED Phototherapy product line, including the neoBLUE, neoBLUE mini, neoBLUE cozy & neoBLUE blanket devices. Natus neoBLUE LED Therapy Radiometer BUY IT HERE: Find out more regarding this listing and DCSP MEDICAL by visiting us OR by. The neoBLUE® radiometer provides a precise measurement of light in the blue spectrum to ensure optimal phototherapy treatment.